®
Microwave Hood Combination
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
MHE14X
Electrical: A 120-volt, 60-Hz, AC-only, 15- or 20-
amp. electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.
16-1/4"
29-7/8"
15-3/8"
CABINET OPENING DIMENSIONS
12" to 14" recommended
cabinet depth
30" min. cabinet
opening width.
30" min.
66" min.
top of wall
mounting plate
to floor
to cooking
surface
below
microwave
hood
NOTE: There must be
at least one wall stud
within cabinet
opening.
wall studs
VENTING REQUIREMENTS
Roof venting
Wall venting
roof cap
Recommended vent length
Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
wall cap
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.
3-1/4" x 10"
through-the-wall
3-1/4" x 10"
through-the-roof
3-1/4" x 10" vent system
For wall or roof venting methods:
Recommended standard fittings
3-1/4" x 10"
If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall for the
exhaust vent.
90° elbow
wall cap
6 ft.
Wall and roof caps must have back-draft damper.
We recommend:
✔ using rigid metal vent.
1 - 3-1/4" x 10"
90° elbow
2 ft.
= 25 ft.
= 40 ft.
3-1/4" x 10"
90° elbow = 25 ft.
3-1/4" x 10"
to 6" = 5 ft.
3-1/4" x 10"
roof cap = 24 ft.
✔ that length of vent and number of elbows should
be kept to a minimum to provide efficient
performance.
1 - wall cap
8 feet straight
Length of
=
8 ft.
✔ that size of vent should be uniform.
✔ using duct tape to seal all joints in the vent
system.
✔ using caulking compound to seal exterior wall or
roof opening around cap.
✔ two elbows should not be installed together.
3-1/4" x 10" system
= 73 ft.
6" vent system
90° elbow
3-1/4" x 10"
flat elbow =
10 ft.
3-1/4" x 10" 45° elbow
90° elbows
6 ft.
= 10 ft.
wall cap =
40 ft.
= 5 ft.
If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.
We do NOT recommend:
✔ flexible metal vent.
1 - transition
2 - 90° elbows
1 - wall cap
= 5 ft.
= 20 ft.
= 40 ft.
2 ft.
NOTE: If flexible metal vent must be used, calculate
each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.
8 feet straight
=
8 ft.
Length of 6" system = 73 ft.
transition
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8184732
04-21-03
|